1
0
mirror of https://github.com/arkuznetsov/1CFilesConverter.git synced 2025-02-19 19:00:09 +02:00
1CFilesConverter/scripts/dp-bin2edt.cmd

102 lines
3.4 KiB
Batchfile
Raw Normal View History

@ECHO OFF
rem Convert (dump) 1C data processor or report from binary format (*.epf, *.erf) to 1C:EDT format
rem %1 - path to 1C data processor or report (*.epf, *.erf)
rem %2 - path to folder to save data processor & report in 1C:EDT format
rem %3 - path to 1C configuration (binary (*.cf), 1C:Designer XML format or 1C:EDT format)
rem or folder contains 1C infobase used for convertion
if not defined V8_VERSION set V8_VERSION=8.3.20.2290
if not defined V8_TEMP set V8_TEMP=%TEMP%\1c
set V8_TOOL="C:\Program Files\1cv8\%V8_VERSION%\bin\1cv8.exe"
FOR /F "usebackq tokens=1 delims=" %%i IN (`where ring`) DO (
set RING_TOOL="%%i"
)
set IB_PATH=%V8_TEMP%\tmp_db
set XML_PATH=%V8_TEMP%\tmp_xml
set WS_PATH=%V8_TEMP%\edt_ws
set CLEAN_AFTER_EXPORT=0
set DP_FILE=%1
if defined DP_FILE set DP_FILE=%DP_FILE:"=%
set DP_PATH=%2
if defined DP_PATH set DP_PATH=%DP_PATH:"=%
set BASE_CONFIG=%3
if defined BASE_CONFIG set BASE_CONFIG=%BASE_CONFIG:"=%
if not defined DP_FILE (
echo Missed parameter 1 "path to 1C data processor or report (*.epf, *.erf)"
exit /b 1
)
if not defined DP_PATH (
echo Missed parameter 2 "path to folder to save data processor & report in 1C:EDT format"
exit /b 1
)
if not exist "%BASE_CONFIG%" (
echo Path "%BASE_CONFIG%" doesn't exist ^(parameter 3^), empty infobase will be used.
set BASE_CONFIG=
)
echo Set infobase for export data processor/report...
IF "%BASE_CONFIG%" equ "" (
echo Creating infobase "%IB_PATH%"...
set CLEAN_AFTER_EXPORT=1
set BASE_CONFIG_DESCRIPTION=empty configuration
%V8_TOOL% CREATEINFOBASE File=%IB_PATH%; /DisableStartupDialogs
) else (
set BASE_CONFIG_DESCRIPTION=configuration from "%BASE_CONFIG%"
IF exist "%BASE_CONFIG%\DT-INF\" (
set CLEAN_AFTER_EXPORT=1
call %~dp0edt2ib.cmd "%BASE_CONFIG%" "%IB_PATH%"
) else (
IF exist "%BASE_CONFIG%\Configuration.xml" (
set CLEAN_AFTER_EXPORT=1
call %~dp0xml2ib.cmd "%BASE_CONFIG%" "%IB_PATH%"
) else (
IF exist "%BASE_CONFIG%\1cv8.1cd" (
set BASE_CONFIG_DESCRIPTION=existed configuration
set IB_PATH=%BASE_CONFIG%
) else (
set CLEAN_AFTER_EXPORT=1
call %~dp0cf2ib.cmd "%BASE_CONFIG%" "%IB_PATH%"
)
)
)
)
echo Clear temporary files...
IF "%CLEAN_AFTER_EXPORT%" equ "1" (
rd /S /Q "%IB_PATH%"
)
if exist "%XML_PATH%" (
rd /S /Q "%XML_PATH%"
)
if exist "%WS_PATH%" (
rd /S /Q "%WS_PATH%"
)
if exist "%DP_PATH%" (
rd /S /Q "%DP_PATH%"
)
md "%XML_PATH%"
md "%WS_PATH%"
md "%DP_PATH%"
echo Export dataprocessor / report "%DP_FILE%" to 1C:Designer XML format "%XML_PATH%" using infobase "%IB_PATH%" with %BASE_CONFIG_DESCRIPTION%...
%V8_TOOL% DESIGNER /IBConnectionString File="%IB_PATH%"; /DisableStartupDialogs /DumpExternalDataProcessorOrReportToFiles "%XML_PATH%" "%DP_FILE%"
echo Export dataprocessor / report from 1C:Designer XML format "%XML_PATH%" to 1C:EDT format "%DP_PATH%"...
call %RING_TOOL% edt workspace import --project "%DP_PATH%" --configuration-files "%XML_PATH%" --workspace-location "%WS_PATH%" --version "%V8_VERSION%"
echo Clear temporary files...
IF "%CLEAN_AFTER_EXPORT%" equ "1" (
rd /S /Q "%IB_PATH%"
)
if exist "%XML_PATH%" (
rd /S /Q "%XML_PATH%"
)
if exist "%WS_PATH%" (
rd /S /Q "%WS_PATH%"
)