mirror of
https://github.com/arkuznetsov/1CFilesConverter.git
synced 2024-11-24 08:33:30 +02:00
feat: Добавлен вывод сообщений конфигуратора в общий лог выполнения.
This commit is contained in:
parent
0e1f1b6852
commit
3ad760edca
@ -160,11 +160,14 @@ IF not ERRORLEVEL 0 (
|
||||
IF not exist "%IB_PATH%" md "%IB_PATH%"
|
||||
|
||||
IF "%V8_CONVERT_TOOL%" equ "designer" (
|
||||
set V8_DESIGNER_LOG=%LOCAL_TEMP%\v8_designer_output.log
|
||||
echo [INFO] Creating infobase "%IB_PATH%"...
|
||||
%V8_TOOL% CREATEINFOBASE %V8_IB_CONNECTION% /DisableStartupDialogs
|
||||
%V8_TOOL% CREATEINFOBASE %V8_IB_CONNECTION% /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!"
|
||||
FOR /F "tokens=* delims=" %%i IN (!V8_DESIGNER_LOG!) DO IF "%%i" neq "" echo [WARN] %%i
|
||||
|
||||
echo [INFO] Loading infobase "%IB_PATH%" configuration from XML-files "%XML_PATH%"...
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_IB_CONNECTION% /DisableStartupDialogs /LoadConfigFromFiles "%XML_PATH%"
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_IB_CONNECTION% /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!" /LoadConfigFromFiles "%XML_PATH%"
|
||||
FOR /F "tokens=* delims=" %%i IN (!V8_DESIGNER_LOG!) DO IF "%%i" neq "" echo [WARN] %%i
|
||||
) ELSE (
|
||||
echo [INFO] Creating infobase "%IB_PATH%" with configuration from XML-files "%XML_PATH%"...
|
||||
%IBCMD_TOOL% infobase create --db-path="%IB_PATH%" --create-database --import="%XML_PATH%"
|
||||
@ -178,7 +181,9 @@ IF not ERRORLEVEL 0 (
|
||||
|
||||
echo [INFO] Export infobase "%IB_PATH%" configuration to "%V8_DST_PATH%"...
|
||||
IF "%V8_CONVERT_TOOL%" equ "designer" (
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /DumpCfg "%V8_DST_PATH%"
|
||||
set V8_DESIGNER_LOG=%LOCAL_TEMP%\v8_designer_output.log
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!" /DumpCfg "%V8_DST_PATH%"
|
||||
FOR /F "tokens=* delims=" %%i IN (!V8_DESIGNER_LOG!) DO IF "%%i" neq "" echo [WARN] %%i
|
||||
) ELSE (
|
||||
IF defined V8_IB_SERVER (
|
||||
%IBCMD_TOOL% infobase config save --dbms=%V8_DB_SRV_DBMS% --db-server=%V8_IB_SERVER% --db-name="%V8_IB_NAME%" --db-user="%V8_DB_SRV_USR%" --db-pwd="%V8_DB_SRV_PWD%" --user="%V8_IB_USER%" --password="%V8_IB_PWD%" "%V8_DST_PATH%"
|
||||
|
@ -137,7 +137,7 @@ echo [INFO] Creating infobase "%IB_PATH%" from file "%V8_SRC_PATH%"...
|
||||
IF not exist "%IB_PATH%" md "%IB_PATH%"
|
||||
|
||||
IF "%V8_CONVERT_TOOL%" equ "designer" (
|
||||
%V8_TOOL% CREATEINFOBASE %V8_IB_CONNECTION% /DisableStartupDialogs /UseTemplate "%V8_SRC_PATH%"
|
||||
%V8_TOOL% CREATEINFOBASE %V8_IB_CONNECTION% /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!" /UseTemplate "%V8_SRC_PATH%"
|
||||
) ELSE (
|
||||
IF defined V8_IB_SERVER (
|
||||
%IBCMD_TOOL% infobase create --dbms=%V8_DB_SRV_DBMS% --db-server=%V8_IB_SERVER% --db-name="%V8_IB_NAME%" --db-user="%V8_DB_SRV_USR%" --db-pwd="%V8_DB_SRV_PWD%" --create-database --load="%V8_SRC_PATH%"
|
||||
@ -157,7 +157,9 @@ echo [INFO] Export configuration from infobase "%IB_PATH%" to 1C:Designer XML fo
|
||||
md "%XML_PATH%"
|
||||
|
||||
IF "%V8_CONVERT_TOOL%" equ "designer" (
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /DumpConfigToFiles "%XML_PATH%" -force
|
||||
set V8_DESIGNER_LOG=%LOCAL_TEMP%\v8_designer_output.log
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!" /DumpConfigToFiles "%XML_PATH%" -force
|
||||
FOR /F "tokens=* delims=" %%i IN (!V8_DESIGNER_LOG!) DO IF "%%i" neq "" echo [WARN] %%i
|
||||
) ELSE (
|
||||
IF defined V8_IB_SERVER (
|
||||
%IBCMD_TOOL% infobase config export --dbms=%V8_DB_SRV_DBMS% --db-server=%V8_IB_SERVER% --db-name="%V8_IB_NAME%" --db-user="%V8_DB_SRV_USR%" --db-pwd="%V8_DB_SRV_PWD%" --user="%V8_IB_USER%" --password="%V8_IB_PWD%" "%XML_PATH%" --force
|
||||
|
@ -186,12 +186,15 @@ IF not ERRORLEVEL 0 (
|
||||
:export_xml
|
||||
|
||||
IF "%V8_CONVERT_TOOL%" equ "designer" (
|
||||
set V8_DESIGNER_LOG=%LOCAL_TEMP%\v8_designer_output.log
|
||||
IF "%V8_IB_CREATE%" equ "1" (
|
||||
echo [INFO] Creating infobase "%IB_PATH%"...
|
||||
%V8_TOOL% CREATEINFOBASE %V8_IB_CONNECTION% /DisableStartupDialogs
|
||||
%V8_TOOL% CREATEINFOBASE %V8_IB_CONNECTION% /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!"
|
||||
FOR /F "tokens=* delims=" %%i IN (!V8_DESIGNER_LOG!) DO IF "%%i" neq "" echo [WARN] %%i
|
||||
)
|
||||
echo [INFO] Loading infobase "%IB_PATH%" configuration from XML-files "%XML_PATH%"...
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /LoadConfigFromFiles "%XML_PATH%"
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!" /LoadConfigFromFiles "%XML_PATH%"
|
||||
FOR /F "tokens=* delims=" %%i IN (!V8_DESIGNER_LOG!) DO IF "%%i" neq "" echo [WARN] %%i
|
||||
) ELSE (
|
||||
IF defined V8_IB_SERVER (
|
||||
IF "%V8_IB_CREATE%" equ "1" (
|
||||
@ -217,13 +220,15 @@ goto finally
|
||||
:export_cf
|
||||
|
||||
IF "%V8_CONVERT_TOOL%" equ "designer" (
|
||||
set V8_DESIGNER_LOG=%LOCAL_TEMP%\v8_designer_output.log
|
||||
IF "%V8_IB_CREATE%" equ "1" (
|
||||
echo [INFO] Creating infobase "%IB_PATH%" from file "%V8_SRC_PATH%"...
|
||||
%V8_TOOL% CREATEINFOBASE %V8_IB_CONNECTION% /DisableStartupDialogs /UseTemplate "%V8_SRC_PATH%"
|
||||
%V8_TOOL% CREATEINFOBASE %V8_IB_CONNECTION% /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!" /UseTemplate "%V8_SRC_PATH%"
|
||||
) ELSE (
|
||||
echo [INFO] Loading infobase "%IB_PATH%" configuration from file "%V8_SRC_PATH%"...
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /LoadCfg "%V8_SRC_PATH%"
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!" /LoadCfg "%V8_SRC_PATH%"
|
||||
)
|
||||
FOR /F "tokens=* delims=" %%i IN (!V8_DESIGNER_LOG!) DO IF "%%i" neq "" echo [WARN] %%i
|
||||
) ELSE (
|
||||
IF defined V8_IB_SERVER (
|
||||
IF "%V8_IB_CREATE%" equ "1" (
|
||||
|
@ -135,7 +135,7 @@ echo [INFO] Creating infobase "%IB_PATH%" from file "%V8_SRC_PATH%"...
|
||||
IF not exist "%IB_PATH%" md "%IB_PATH%"
|
||||
|
||||
IF "%V8_CONVERT_TOOL%" equ "designer" (
|
||||
%V8_TOOL% CREATEINFOBASE %V8_IB_CONNECTION% /DisableStartupDialogs /UseTemplate "%V8_SRC_PATH%"
|
||||
%V8_TOOL% CREATEINFOBASE %V8_IB_CONNECTION% /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!" /UseTemplate "%V8_SRC_PATH%"
|
||||
) ELSE (
|
||||
IF defined V8_IB_SERVER (
|
||||
%IBCMD_TOOL% infobase create --dbms=%V8_DB_SRV_DBMS% --db-server=%V8_IB_SERVER% --db-name="%V8_IB_NAME%" --db-user="%V8_DB_SRV_USR%" --db-pwd="%V8_DB_SRV_PWD%" --create-database --load="%V8_SRC_PATH%"
|
||||
@ -152,7 +152,9 @@ IF not ERRORLEVEL 0 (
|
||||
|
||||
echo [INFO] Export configuration from infobase "%IB_PATH%" to 1C:Designer XML format "%V8_DST_PATH%"...
|
||||
IF "%V8_CONVERT_TOOL%" equ "designer" (
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /DumpConfigToFiles "%V8_DST_PATH%" -force
|
||||
set V8_DESIGNER_LOG=%LOCAL_TEMP%\v8_designer_output.log
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!" /DumpConfigToFiles "%V8_DST_PATH%" -force
|
||||
FOR /F "tokens=* delims=" %%i IN (!V8_DESIGNER_LOG!) DO IF "%%i" neq "" echo [WARN] %%i
|
||||
) ELSE (
|
||||
IF defined V8_IB_SERVER (
|
||||
%IBCMD_TOOL% infobase config export --dbms=%V8_DB_SRV_DBMS% --db-server=%V8_IB_SERVER% --db-name="%V8_IB_NAME%" --db-user="%V8_DB_SRV_USR%" --db-pwd="%V8_DB_SRV_PWD%" --user="%V8_IB_USER%" --password="%V8_IB_PWD%" "%V8_DST_PATH%" --force
|
||||
|
@ -106,7 +106,7 @@ IF "%V8_BASE_IB%" equ "" (
|
||||
md "%IB_PATH%"
|
||||
echo [INFO] Creating temporary file infobase "%IB_PATH%"...
|
||||
set V8_BASE_IB_CONNECTION=File="%IB_PATH%";
|
||||
%V8_TOOL% CREATEINFOBASE !V8_BASE_IB_CONNECTION! /DisableStartupDialogs
|
||||
%V8_TOOL% CREATEINFOBASE !V8_BASE_IB_CONNECTION! /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!"
|
||||
goto prepare_ib
|
||||
)
|
||||
IF /i "%V8_BASE_IB:~0,2%" equ "/F" (
|
||||
@ -188,9 +188,12 @@ echo [INFO] Export data processors ^& reports from folder "%V8_SRC_PATH%" to 1C:
|
||||
|
||||
md "%XML_PATH%"
|
||||
|
||||
set V8_DESIGNER_LOG=%LOCAL_TEMP%\v8_designer_output.log
|
||||
|
||||
FOR /F "delims=" %%f IN ('dir /b /a-d %V8_SRC_MASK%') DO (
|
||||
echo [INFO] Building %%~nf...
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_BASE_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /DumpExternalDataProcessorOrReportToFiles "%XML_PATH%" "%V8_SRC_FOLDER%\%%~nxf"
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_BASE_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!" /DumpExternalDataProcessorOrReportToFiles "%XML_PATH%" "%V8_SRC_FOLDER%\%%~nxf"
|
||||
FOR /F "tokens=* delims=" %%i IN (!V8_DESIGNER_LOG!) DO IF "%%i" neq "" echo [WARN] %%i
|
||||
IF not ERRORLEVEL 0 (
|
||||
set ERROR_CODE=%ERRORLEVEL%
|
||||
goto finally
|
||||
|
@ -106,7 +106,7 @@ IF "%V8_BASE_IB%" equ "" (
|
||||
md "%IB_PATH%"
|
||||
echo [INFO] Creating temporary file infobase "%IB_PATH%"...
|
||||
set V8_BASE_IB_CONNECTION=File="%IB_PATH%";
|
||||
%V8_TOOL% CREATEINFOBASE !V8_BASE_IB_CONNECTION! /DisableStartupDialogs
|
||||
%V8_TOOL% CREATEINFOBASE !V8_BASE_IB_CONNECTION! /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!"
|
||||
goto prepare_ib
|
||||
)
|
||||
IF /i "%V8_BASE_IB:~0,2%" equ "/F" (
|
||||
@ -203,23 +203,28 @@ IF not ERRORLEVEL 0 (
|
||||
|
||||
:export_xml
|
||||
|
||||
set V8_DESIGNER_LOG=%LOCAL_TEMP%\v8_designer_output.log
|
||||
|
||||
IF "%V8_SRC_IS_EDT%" equ "1" (
|
||||
echo [INFO] Import external data processors from "%XML_PATH%" to 1C:Designer format "%V8_DST_PATH%" using infobase "%IB_PATH%"...
|
||||
FOR /F "delims=" %%f IN ('dir /b /a-d "%XML_PATH%\ExternalDataProcessors\*.xml"') DO (
|
||||
echo [INFO] Building %%~nf...
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_BASE_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /LoadExternalDataProcessorOrReportFromFiles "%XML_PATH%\ExternalDataProcessors\%%~nxf" "%V8_DST_PATH%"
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_BASE_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!" /LoadExternalDataProcessorOrReportFromFiles "%XML_PATH%\ExternalDataProcessors\%%~nxf" "%V8_DST_PATH%"
|
||||
FOR /F "tokens=* delims=" %%i IN (!V8_DESIGNER_LOG!) DO IF "%%i" neq "" echo [WARN] %%i
|
||||
)
|
||||
echo [INFO] Import external reports from "%XML_PATH%" to 1C:Designer format "%V8_DST_PATH%" using infobase "%IB_PATH%"...
|
||||
FOR /F "delims=" %%f IN ('dir /b /a-d "%XML_PATH%\ExternalReports\*.xml"') DO (
|
||||
echo [INFO] Building %%~nf...
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_BASE_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /LoadExternalDataProcessorOrReportFromFiles "%XML_PATH%\ExternalReports\%%~nxf" "%V8_DST_PATH%"
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_BASE_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!" /LoadExternalDataProcessorOrReportFromFiles "%XML_PATH%\ExternalReports\%%~nxf" "%V8_DST_PATH%"
|
||||
FOR /F "tokens=* delims=" %%i IN (!V8_DESIGNER_LOG!) DO IF "%%i" neq "" echo [WARN] %%i
|
||||
)
|
||||
) ELSE (
|
||||
echo [INFO] Import external datap processors ^& reports from "%XML_PATH%" to 1C:Designer format "%V8_DST_PATH%" using infobase "%IB_PATH%"...
|
||||
FOR /F "delims=" %%f IN ('dir /b /a-d %V8_SRC_MASK%') DO (
|
||||
echo [INFO] Building %%~nf...
|
||||
echo %V8_DST_PATH%
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_BASE_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /LoadExternalDataProcessorOrReportFromFiles "%XML_PATH%\%%~nxf" "%V8_DST_PATH%"
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_BASE_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!" /LoadExternalDataProcessorOrReportFromFiles "%XML_PATH%\%%~nxf" "%V8_DST_PATH%"
|
||||
FOR /F "tokens=* delims=" %%i IN (!V8_DESIGNER_LOG!) DO IF "%%i" neq "" echo [WARN] %%i
|
||||
)
|
||||
)
|
||||
set ERROR_CODE=%ERRORLEVEL%
|
||||
|
@ -105,7 +105,7 @@ IF "%V8_BASE_IB%" equ "" (
|
||||
md "%IB_PATH%"
|
||||
echo [INFO] Creating temporary file infobase "%IB_PATH%"...
|
||||
set V8_BASE_IB_CONNECTION=File="%IB_PATH%";
|
||||
%V8_TOOL% CREATEINFOBASE !V8_BASE_IB_CONNECTION! /DisableStartupDialogs
|
||||
%V8_TOOL% CREATEINFOBASE !V8_BASE_IB_CONNECTION! /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!"
|
||||
goto prepare_ib
|
||||
)
|
||||
IF /i "%V8_BASE_IB:~0,2%" equ "/F" (
|
||||
@ -182,9 +182,13 @@ goto finally
|
||||
:export_epf
|
||||
|
||||
echo [INFO] Export data processors ^& reports from folder "%V8_SRC_PATH%" to 1C:Designer XML format "%V8_DST_PATH%" using infobase "%IB_PATH%"...
|
||||
|
||||
set V8_DESIGNER_LOG=%LOCAL_TEMP%\v8_designer_output.log
|
||||
|
||||
FOR /F "delims=" %%f IN ('dir /b /a-d %V8_SRC_MASK%') DO (
|
||||
echo [INFO] Building %%~nf...
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_BASE_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /DumpExternalDataProcessorOrReportToFiles "%V8_DST_PATH%\%%~nf.xml" "%V8_SRC_FOLDER%\%%~nxf"
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_BASE_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!" /DumpExternalDataProcessorOrReportToFiles "%V8_DST_PATH%\%%~nf.xml" "%V8_SRC_FOLDER%\%%~nxf"
|
||||
FOR /F "tokens=* delims=" %%i IN (!V8_DESIGNER_LOG!) DO IF "%%i" neq "" echo [WARN] %%i
|
||||
)
|
||||
set ERROR_CODE=%ERRORLEVEL%
|
||||
goto finally
|
||||
|
@ -120,7 +120,7 @@ IF "%V8_BASE_IB%" equ "" (
|
||||
md "%IB_PATH%"
|
||||
echo [INFO] Creating temporary file infobase "%IB_PATH%"...
|
||||
set V8_BASE_IB_CONNECTION=File="%IB_PATH%";
|
||||
%V8_TOOL% CREATEINFOBASE !V8_BASE_IB_CONNECTION! /DisableStartupDialogs
|
||||
%V8_TOOL% CREATEINFOBASE !V8_BASE_IB_CONNECTION! /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!"
|
||||
goto prepare_ib
|
||||
)
|
||||
IF /i "%V8_BASE_IB:~0,2%" equ "/F" (
|
||||
@ -211,7 +211,9 @@ IF not ERRORLEVEL 0 (
|
||||
|
||||
echo [INFO] Loading configuration extension from XML-files "%XML_PATH%" to infobase "%IB_PATH%"...
|
||||
IF "%V8_CONVERT_TOOL%" equ "designer" (
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_BASE_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /LoadConfigFromFiles "%XML_PATH%" -Extension %V8_EXT_NAME%
|
||||
set V8_DESIGNER_LOG=%LOCAL_TEMP%\v8_designer_output.log
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_BASE_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!" /LoadConfigFromFiles "%XML_PATH%" -Extension %V8_EXT_NAME%
|
||||
FOR /F "tokens=* delims=" %%i IN (!V8_DESIGNER_LOG!) DO IF "%%i" neq "" echo [WARN] %%i
|
||||
) ELSE (
|
||||
IF defined V8_BASE_IB_SERVER (
|
||||
%IBCMD_TOOL% infobase config import --dbms=%V8_DB_SRV_DBMS% --db-server=%V8_BASE_IB_SERVER% --db-name="%V8_BASE_IB_NAME%" --db-user="%V8_DB_SRV_USR%" --db-pwd="%V8_DB_SRV_PWD%" --user="%V8_IB_USER%" --password="%V8_IB_PWD%" --extension=%V8_EXT_NAME% "%XML_PATH%"
|
||||
@ -228,7 +230,9 @@ IF not ERRORLEVEL 0 (
|
||||
|
||||
echo [INFO] Export configuration extension from infobase "%IB_PATH%" configuration to "%V8_DST_PATH%"...
|
||||
IF "%V8_CONVERT_TOOL%" equ "designer" (
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_BASE_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /DumpCfg "%V8_DST_PATH%" -Extension %V8_EXT_NAME%
|
||||
set V8_DESIGNER_LOG=%LOCAL_TEMP%\v8_designer_output.log
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_BASE_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!" /DumpCfg "%V8_DST_PATH%" -Extension %V8_EXT_NAME%
|
||||
FOR /F "tokens=* delims=" %%i IN (!V8_DESIGNER_LOG!) DO IF "%%i" neq "" echo [WARN] %%i
|
||||
) ELSE (
|
||||
IF defined V8_BASE_IB_SERVER (
|
||||
%IBCMD_TOOL% infobase config save --dbms=%V8_DB_SRV_DBMS% --db-server=%V8_BASE_IB_SERVER% --db-name="%V8_BASE_IB_NAME%" --db-user="%V8_DB_SRV_USR%" --db-pwd="%V8_DB_SRV_PWD%" --user="%V8_IB_USER%" --password="%V8_IB_PWD%" --extension=%V8_EXT_NAME% "%V8_DST_PATH%"
|
||||
|
@ -118,7 +118,7 @@ IF "%V8_BASE_IB%" equ "" (
|
||||
md "%IB_PATH%"
|
||||
echo [INFO] Creating temporary file infobase "%IB_PATH%"...
|
||||
set V8_BASE_IB_CONNECTION=File="%IB_PATH%";
|
||||
%V8_TOOL% CREATEINFOBASE !V8_BASE_IB_CONNECTION! /DisableStartupDialogs
|
||||
%V8_TOOL% CREATEINFOBASE !V8_BASE_IB_CONNECTION! /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!"
|
||||
goto prepare_ib
|
||||
)
|
||||
IF /i "%V8_BASE_IB:~0,2%" equ "/F" (
|
||||
@ -185,7 +185,9 @@ goto finally
|
||||
echo [INFO] Loading configuration extension from file "%V8_SRC_PATH%" to infobase "%IB_PATH%"...
|
||||
|
||||
IF "%V8_CONVERT_TOOL%" equ "designer" (
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_BASE_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /LoadCfg "%V8_SRC_PATH%" -Extension %V8_EXT_NAME%
|
||||
set V8_DESIGNER_LOG=%LOCAL_TEMP%\v8_designer_output.log
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_BASE_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!" /LoadCfg "%V8_SRC_PATH%" -Extension %V8_EXT_NAME%
|
||||
FOR /F "tokens=* delims=" %%i IN (!V8_DESIGNER_LOG!) DO IF "%%i" neq "" echo [WARN] %%i
|
||||
) ELSE (
|
||||
IF defined V8_BASE_IB_SERVER (
|
||||
%IBCMD_TOOL% infobase config load --dbms=%V8_DB_SRV_DBMS% --db-server=%V8_BASE_IB_SERVER% --db-name="%V8_BASE_IB_NAME%" --db-user="%V8_DB_SRV_USR%" --db-pwd="%V8_DB_SRV_PWD%" --user="%V8_IB_USER%" --password="%V8_IB_PWD%" --extension=%V8_EXT_NAME% "%V8_SRC_PATH%"
|
||||
@ -199,7 +201,9 @@ echo [INFO] Export configuration extension from infobase "%IB_PATH%" to 1C:Desig
|
||||
md %XML_PATH%
|
||||
|
||||
IF "%V8_CONVERT_TOOL%" equ "designer" (
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_BASE_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /DumpConfigToFiles "%XML_PATH%" -Extension %V8_EXT_NAME% -force
|
||||
set V8_DESIGNER_LOG=%LOCAL_TEMP%\v8_designer_output.log
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_BASE_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!" /DumpConfigToFiles "%XML_PATH%" -Extension %V8_EXT_NAME% -force
|
||||
FOR /F "tokens=* delims=" %%i IN (!V8_DESIGNER_LOG!) DO IF "%%i" neq "" echo [WARN] %%i
|
||||
) ELSE (
|
||||
IF defined V8_BASE_IB_SERVER (
|
||||
%IBCMD_TOOL% infobase config export --dbms=%V8_DB_SRV_DBMS% --db-server=%V8_BASE_IB_SERVER% --db-name="%V8_BASE_IB_NAME%" --db-user="%V8_DB_SRV_USR%" --db-pwd="%V8_DB_SRV_PWD%" --user="%V8_IB_USER%" --password="%V8_IB_PWD%" --extension=%V8_EXT_NAME% --force "%XML_PATH%"
|
||||
|
@ -117,7 +117,7 @@ IF "%V8_BASE_IB%" equ "" (
|
||||
md "%IB_PATH%"
|
||||
echo [INFO] Creating temporary file infobase "%IB_PATH%"...
|
||||
set V8_BASE_IB_CONNECTION=File="%IB_PATH%";
|
||||
%V8_TOOL% CREATEINFOBASE !V8_BASE_IB_CONNECTION! /DisableStartupDialogs
|
||||
%V8_TOOL% CREATEINFOBASE !V8_BASE_IB_CONNECTION! /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!"
|
||||
goto prepare_ib
|
||||
)
|
||||
IF /i "%V8_BASE_IB:~0,2%" equ "/F" (
|
||||
@ -185,7 +185,9 @@ goto finally
|
||||
echo [INFO] Loading configuration extension from file "%V8_SRC_PATH%" to infobase "%IB_PATH%"...
|
||||
|
||||
IF "%V8_CONVERT_TOOL%" equ "designer" (
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_BASE_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /LoadCfg "%V8_SRC_PATH%" -Extension %V8_EXT_NAME%
|
||||
set V8_DESIGNER_LOG=%LOCAL_TEMP%\v8_designer_output.log
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_BASE_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!" /LoadCfg "%V8_SRC_PATH%" -Extension %V8_EXT_NAME%
|
||||
FOR /F "tokens=* delims=" %%i IN (!V8_DESIGNER_LOG!) DO IF "%%i" neq "" echo [WARN] %%i
|
||||
) ELSE (
|
||||
IF defined V8_BASE_IB_SERVER (
|
||||
%IBCMD_TOOL% infobase config load --dbms=%V8_DB_SRV_DBMS% --db-server=%V8_BASE_IB_SERVER% --db-name="%V8_BASE_IB_NAME%" --db-user="%V8_DB_SRV_USR%" --db-pwd="%V8_DB_SRV_PWD%" --user="%V8_IB_USER%" --password="%V8_IB_PWD%" --extension=%V8_EXT_NAME% "%V8_SRC_PATH%"
|
||||
@ -197,7 +199,9 @@ IF "%V8_CONVERT_TOOL%" equ "designer" (
|
||||
echo [INFO] Export configuration from infobase "%IB_PATH%" to 1C:Designer XML format "%V8_DST_PATH%"...
|
||||
|
||||
IF "%V8_CONVERT_TOOL%" equ "designer" (
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_BASE_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /DumpConfigToFiles "%V8_DST_PATH%" -Extension %V8_EXT_NAME% -force
|
||||
set V8_DESIGNER_LOG=%LOCAL_TEMP%\v8_designer_output.log
|
||||
%V8_TOOL% DESIGNER /IBConnectionString %V8_BASE_IB_CONNECTION% /N"%V8_IB_USER%" /P"%V8_IB_PWD%" /DisableStartupDialogs /Out "!V8_DESIGNER_LOG!" /DumpConfigToFiles "%V8_DST_PATH%" -Extension %V8_EXT_NAME% -force
|
||||
FOR /F "tokens=* delims=" %%i IN (!V8_DESIGNER_LOG!) DO IF "%%i" neq "" echo [WARN] %%i
|
||||
) ELSE (
|
||||
IF defined V8_BASE_IB_SERVER (
|
||||
%IBCMD_TOOL% infobase config load --dbms=%V8_DB_SRV_DBMS% --db-server=%V8_BASE_IB_SERVER% --db-name="%V8_BASE_IB_NAME%" --db-user="%V8_DB_SRV_USR%" --db-pwd="%V8_DB_SRV_PWD%" --user="%V8_IB_USER%" --password="%V8_IB_PWD%" --extension=%V8_EXT_NAME% --force "%V8_DST_PATH%"
|
||||
|
Loading…
Reference in New Issue
Block a user